مضخة تعزيز الغاز سلسلة OMD

لتعزيز ضغط الغاز المدفوع بالهواء وإنتاج ضغط عالي متوقع.

منضدة اختبار صمام الأمان

منضدة اختبار الصمامات

معدات اختبار الضغط

مضخة تعزيز الغاز المعززة

مضخة معززة للسوائل

معدات اختبار مقياس الضغط

صمامات مشعب الأدوات

صمام إبرة الضغط العالي الضغط

ماكينة معالجة قضبان التوصيل

ضاغط الغاز المختلط

تركيب الطويق

مضخة تعزيز الغاز سلسلة OMD

مضخة تعزيز الغاز سلسلة OMD
مضخة تعزيز الغاز سلسلة OMD

مقدمة المنتج

The OMD Series Gas Booster Pumps are air-driven pneumatic gas booster pumps designed for boosting and compressing industrial gases such as air, nitrogen, oxygen, helium, hydrogen, and other gases. This series is engineered for applications where stable, adjustable high-pressure gas output is required, and where an air-driven (no electricity) boosting principle is preferred.

The OMD series provides a broad model range from low ratio to ultra-high ratio boosters, including OMD80-2 (160:1) and OMD100-2 (200:1) variants, enabling system designers to match inlet pressure conditions and target outlet pressure precisely.

وصف المنتج

The OMD Series Gas Booster Pumps are air-driven pneumatic boosters. Compressed air is used as the driving source (PL, 1–8 bar), and the gas inlet pressure (PA) is boosted to a higher outlet pressure (PB) according to the model’s design.

In the latest OMD selection table, the gas outlet pressure is defined model-by-model as:

PB = k × PL + PA

where k is the multiplier specified in the table for each model (for example: 1×, 1.6×, 2.5×, 4×, 10×, 16×, 25×, 40×, 60×, 80×, 100×, 160×, 200×).
Because k is not always identical to the numeric “pressure ratio” label in every case, the correct PB calculation and selection must follow the Gas outlet pressure row and Pump stop pressure PB row in the table for the specific model you choose.

The OMD series includes OMD standard models and higher-pressure variants such as OMD80-2 (160:1) and OMD100-2 (200:1).

مضخة تعزيز الغاز سلسلة OMD

مضخة تعزيز الغاز سلسلة OMD

المعلمات الفنية OMD02 OMD04 OMD10 OMD16 OMD25 OMD40 OMD60 OMD80 OMD100
نسبة الضغط 2.5:1 4:1 10:1 16:1 25:1 40:1 60:1 80:1 100:1
Max. Compression Ratio 10:1 15:1 15:1 20:1 20:1 20:1 20:1 20:1 20:1
Min. Gas Inlet Pressure PA (bar) 1 2 4 7 12 20 30 35 40
Max. Gas Inlet Pressure PA (bar) 20 40 80 128 200 320 480 640 800
Gas Outlet Pressure PB (bar) 2.5PL+PA 4PL+PA 10PL+PA 16PL+PA 25PL+PA 40PL+PA 60PL+PA 80PL+PA 100PL+PA
Max. Gas Outlet Pressure PB (bar) 40 64 80 128 200 320 480 640 800
Single Stroke Capacity (ml) 1570 1004 392 250 160 98 62 50 40
ضغط الهواء المدفوع PL (بار) 1-8 1-8 1-8 1-8 1-8 1-8 1-8 1-8 1-8
حجم منفذ الهواء المدفوع ZG1/2 ″ ZG1/2 ″ ZG1/2 ″ ZG1/2 ″ ZG1/2 ″ ZG1/2 ″ ZG1/2 ″ ZG1/2 ″ ZG1/2 ″
منفذ مدخل متوسط الحجم ZG1/2 ″ ZG1/2 ″ ZG1/2 ″ ZG1/2 ″ ZG1/4 ″ ZG1/4 ″ ZG1/4 ″ ZG1/4 ″ ZG1/4 ″
منفذ خروج متوسط الحجم ZG1/2 ″ ZG1/2 ″ ZG1/4 ″ ZG1/4 ″ ZG1/4 ″ ZG1/4 ″ ZG1/4 ″ ZG1/4″/M14*1.5 M14*1.5
Pump Material Aluminum Alloy / Stainless Steel
Max. Working Frequency (times/min) 60 60 60 60 60 60 60 60 60
توقف المضخة ضغط إيقاف المضخة PB 2.5PL+PA 4PL+PA 10PL+PA 16PL+PA 25PL+PA 40PL+PA 60PL+PA 80PL+PA 100PL+PA
Max. Working Temperature (°C) 60 60 60 60 60 60 60 60 60
الوزن الصافي (كجم) 24 21 23 25 24 25 25 25 25
الأختام القياسية PTFE, FKM, NBR
Dimensions (L×W×H) (mm) 665 × 172 × 273 609 × 172 × 273 590 × 212 × 273 590 × 212 × 273 593 × 212 × 273 593 × 212 × 273 593 × 212 × 273 593 × 212 × 273 593 × 212 × 273
Inert Gas Service (Standard) OMD02NL OMD04NL OMD10NL OMD16NL OMD25NL OMD40NL OMD60NL OMD80NL OMD100NL
Oxygen Service OMD02OL OMD04OL OMD10OL OMD16OL OMD25OL OMD40OL OMD60OL
CO2 Service OMD02CL OMD04CL OMD10CL OMD16CL OMD25CL OMD40CL OMD60CL

 الميزات والوظائف

  • Air-driven boosting (PL 1–8 bar): operates with compressed air as the driving source, suitable for pneumatic systems and non-electric working environments.
  • Predictable outlet pressure formula: the OMD series uses a clear pressure relationship PB = ratio×PL + PA, convenient for system design and pressure calculation.
  • Wide model coverage: pressure ratios from 1.6:1 to 200:1, supporting different boosting targets and inlet pressure conditions.
  • High outlet pressure capability: max PB ranges up to 1600 bar (OMD100-2) per the model selection table.
  • Multiple inlet pressure ranges: PA ranges differ by model, including special conditions such as micro negative pressure and atmospheric pressure entries (as listed for OMD01B/OMD02B).
  • Standardized installation interfaces: consistent driven air port size ZG1/2″, and standardized inlet/outlet port sizes to simplify integration.
  • Material and seal options aligned to service: Aluminum Alloy / Stainless Steel body material and PTFE / FKM / NBR sealing set as standard.
  • Defined operating limits: max working frequency 60 times/min, max working temperature 60°C (all models).
مضخة تعزيز الغاز سلسلة OMD

إذا كنت ترغب في معرفة المزيد عن الموديلات الأخرى، يُرجى الاتصال بفريق خدمة العملاء لدينا.

 

مزايا المنتج

  • Strong engineering selectability: the OMD series table provides direct selection guidance by ratio, PA inlet limits, and PB maximum pressure, reducing selection errors.
  • Broader ratio range than common single-series boosters: supports both standard models and high-ratio -2 models for higher pressure needs.
  • Stable pneumatic drive range: PL 1–8 bar across all models supports common factory air supply conditions.
  • Integration-friendly dimensions: consistent sizes for many mid-range models (OMD10–OMD100 mostly 590–593 mm length with uniform height), supporting skid mounting and compact layouts.
  • Service model coding available: inert gas standard (NL) across all models, with dedicated oxygen (OL) and CO₂ (CL) codes where listed.

 

مزايا شركتنا

Highlight is a manufacturer focused on pressure testing equipment and pneumatic boosting systems. For gas booster pumps and integrated boosting solutions, we provide:

  • 16+ years focused on R&D and production of pressure testing equipment and pneumatic boosting equipment
  • 1000+ sets/year production capacity
  • خدمة أكثر من 8000 عميل
  • National High-Tech Enterprise
  • 28 patents
  • Technical team with 10+ years experience
  • ISO9001 quality system and CE compliance
  • 10+ years export experience to Europe & North America and other overseas markets
  • Support for both complete systems and single-unit supply, with engineering technical support

 

Working Principle of OMD Gas Booster Pumps

OMD gas booster pumps operate with a reciprocating air-driven mechanism:

  • Driving side (PL): compressed air (1–8 bar) drives the piston movement.
  • Gas side (PA → PB): inlet gas pressure PA is boosted to outlet pressure PB based on the selected model’s multiplier k.

For system design and pressure calculation, the outlet pressure relationship is strictly as listed in the selection table:

PB = k × PL + PA (k varies by model and must follow the table)

The pump will automatically stop boosting when the outlet pressure reaches the model’s Pump stop pressure PB value shown in the table, which follows the same k × PL + PA format.

This table-defined pressure logic ensures users can select the correct model by matching:

  • available inlet pressure PA range,
  • available driving pressure PL, and
  • required maximum outlet pressure PB.

المنتجات الموصى بها

احصل على عرض أسعار

    سنرد عليك في غضون 24 ساعة. إذا كانت الحالة عاجلة، يُرجى إضافة واتساب/وي شات: +86 18353183710,. أو اتصل على +86 18353183710 مباشرة.

    *نحن نحترم سريتك وجميع معلوماتك محمية.

    لن نستخدم معلوماتك إلا للرد على استفسارك ولن نرسل أبداً رسائل بريد إلكتروني غير مرغوب فيها أو رسائل ترويجية.