The OGD-2 Series Pneumatic Hydraulic Pump is designed to boost the pressure of oil, water, and chemical media. It features a compact structure with low cost and high efficiency, and works on a reciprocating piston intensifier principle. Driven by compressed air or inert gas, it can reach pressures up to 600 MPa and automatically compensates pressure when outlet pressure drops.

Highlight provides suitable pneumatic hydraulic pumps according to application requirements. The product range includes six series: M, MD, OS, OSD, OG, and OGD, which can meet different pressure and flow requirements, and different media can be matched with different pump types.

Produktbeschreibung

The OGD-2 series is a double-acting pneumatic pump. Compared with the OGD series pump, the OGD-2 series can generate 2× output pressure under the same driving air pressure.

The gas drive components are made of aluminum alloy, and the aluminum alloy parts are treated by oxidation to black finish, ensuring good appearance and corrosion resistance. The liquid end material can be selected as carbon steel or stainless steel according to the working medium. The complete sealing set uses imported high-quality seals to ensure pump performance.

The driving air piston diameter of this series is 160 mm. The maximum driving air pressure is 10 bar. To ensure service life, it is recommended to use driving air pressure ≤ 8 bar.

Pneumatische Hydraulikpumpe der Serie OGD-2

Wenn Sie mehr über andere Modelle erfahren möchten, wenden Sie sich bitte an unseren Kundendienst.

 

Technische Parameter OGD6-2 OGD10-2 OGD16-2 OGD28-2 OGD40-2 OGD64-2 OGD80-2 OGD100-2 OGD130-2 OGD175-2 OGD255-2 OGD400-2
Druckverhältnis 12:1 20:1 32:1 56:1 80:1 128:1 160:1 200:1 260:1 350:1 510:1 800:1
Ausgangsdruck PB (bar) 96 160 256 448 640 1024 1280 1600 2080 2800 4080 6400
Freie Durchflussmenge (L/min) 39.28 24.72 17.01 9.72 6.63 4.32 3.25 2.38 1.98 1.70 1.05 0.69
Angetriebener Luftdruck PL (bar) 1-8 1-8 1-8 1-8 1-8 1-8 1-8 1-8 1-8 1-8 1-8 1-8
Angetriebene Luftanschlussgröße ZG1/2″. ZG1/2″. ZG1/2″. ZG1/2″. ZG1/2″. ZG1/2″. ZG1/2″. ZG1/2″. ZG1/2″. ZG1/2″. ZG1/2″. ZG1/2″.
Medium Einlassöffnung Größe ZG3/4″. ZG3/4″. ZG1/2″. ZG1/2″. ZG3/8″. ZG3/8″. ZG3/8″. ZG3/8″. ZG3/8″. ZG1/4″. ZG1/4″. ZG1/4″.
Medium Auslass Anschlussgröße ZG1/2″. ZG1/2″. ZG3/8″. ZG3/8″. ZG1/4″. ZG1/4″. M14×1.5 M14×1.5 M14×1.5 M14×1.5 M14×1.5 M14×1.5
Material der Druckerhöhungspumpe Aluminiumlegierung/Kohlenstoffstahl/Edelstahl
Maximale Arbeitsfrequenz (Zeiten/min) 60 60 60 60 60 60 60 60 60 60 60 60
Pumpe Stop Druck PB 12PL 20PL 32PL 56PL 80PL 128PL 160PL 200PL 260PL 350PL 510PL 800PL
Maximale Betriebstemperatur (°C) 60 60 60 60 60 60 60 60 60 60 60 60
Nettogewicht (kg) 19.7 19.7 19.7 18.5 18.5 18.5 18.5 18.3  18.3  18.3  18.3  18.3
Standard-Dichtungen Polyurethan / Nitrilkautschuk
Länge (mm) 530 530 461 461 461 461 461 461 461 461 421 421
Breite (mm) 172 172 172 172 172 172 172 172 172 172 172 172
Höhe (mm) 273 273 273 273 273 273 273 273 273 273 273 273
Öleinfüllversion Bestellnummer OGD6-20L OGD10-20L OGD16-20L OGD28-20L OGD40-20L OGD64-20L OGD80-20L OGD100-20L OGD130-20L OGD175-20L OGD255-20L OGD400-20L
Wasserbefüllte Version Bestellnummer OGD6-2WL OGD10-2WL OGD16-2WL OGD28-2WL OGD40-2WL OGD64-2WL OGD80-2WL OGD100-2WL OGD130-2WL OGD175-2WL OGD255-2WL OGD400-2WL
Spezialeinlass und -auslass (z. B. NPT) Bestellnummer OGD6-20L-NPT OGD10-20L-NPT OGD16-20L-NPT OGD28-20L-NPT OGD40-20L-NPT OGD64-20L-NPT OGD80-20L-NPT OGD100-20L-NPT OGD130-20L-NPT OGD175-20L-NPT OGD255-20L-NPT OGD400-20L-NPT

Merkmale und Funktionen

  • Pressure can be adjusted through a manual hydraulic pressure control valve or a pneumatic control valve.
  • Air-driven operation, especially suitable for explosion-proof applications.
  • Er kann den voreingestellten Enddruck erreichen.
  • Automatic pressurization by the pump.
  • Long-term pressure holding with no additional energy consumption.
  • Ensures the medium will not overheat during pressure holding.
  • Easy installation and low maintenance cost: only need to connect air source, inlet line, and pressure line to work.
  • Zuverlässiger Betrieb mit geringen Wartungskosten und geringem Betriebsgeräusch.

 

Produktvorteile

  • Compact structure, low cost, and high efficiency.
  • Driven by compressed air or inert gas; pressure can reach 600 MPa.
  • OGD-2 series produces 2× output pressure compared with OGD series under the same driving air pressure.
  • Aluminum alloy gas drive section with oxidation black finish; liquid end material selectable by medium.
  • Imported high-quality seal set to ensure pump performance.
  • Automatic operation: starts when pressure drops and compensates pressure automatically.

 

Unsere Unternehmensvorteile

Highlight konzentriert sich auf das Design und die Herstellung von Druckprüfgeräten und Systemen zur Fluidkontrolle, unterstützt sowohl Standardmodelle als auch projektbasierte Anpassungen.

  • Über 16 Jahre Erfahrungen mit Druckprüfgeräten und pneumatischen Hebesystemen
  • Jährliche Produktionskapazität: 1000+ Geräte
  • Über 8000 Kunden bedient
  • Implementierung eines auf ISO9001 basierenden Qualitätsmanagementsystems und stabile Fertigungskontrolle
  • Starkes Ingenieurteam für die Konfiguration von Testbänken, Anpassung von Vorrichtungen und technischen Support
  • Erfahrung im Export zur Unterstützung internationaler Käufer mit technischer Kommunikation und Dokumentation

 

Working Temperature & Recommended Drive Air Quality

  • Working temperature: Standard operating temperature range is -20°C to +60°C. (Below 0°C, ensure the driving air source is dry and clean.)
  • Recommended drive air quality (PNEUROP 611/1984):
  • Air quality class: 3–4
  • Particles: max particle size 5 μm, max particle concentration 5 mg/m³
  • Dew point / water content: +10°C: 9.4 g/m³, +2°C: 5.6 g/m³
  • Oil content: 1.0–5 mg/m³
  • Note: Continuous operation with humid gas may cause icing. It is recommended to install a water separator or dryer and use a lubricator to extend seal life.